FORCE W
HIGH POWER CONDENSING BOILER FOR CASCADE INSTALLATION
- High power condensing wall-hung boiler. Designed for single or modular installation until 600 kW
(*Also Force Cascade Insulation available for Outdoors (for more details click here to see more info or call our team).
- Hydraulic, gas and flue gas accessories for the cascade system with 2, 3 and 4 modules
- Heat exchanger with pre-assembled elements in aluminum-silicon alloy. Designed to obtain maximum efficiency and low hydraulic pressure drop
- Complete premix combustion system with a metal fiber burner with very low emissions (Class 6 by EN 15502-1). Boiler can operate with natural gas or LPG
- Safety system of the thermal group:
* Dual sensor (flow and return) for constant Δt operation (set from 0 to 60°C)
* Heat exchanger safety sensor to protect against overheating, set at 95°C
* Flue safety sensor
* Water pressure switch with a minimum level of 0.8 bar
- Hydraulic group (supplied as an accessory) comprising of two sectioning valves (3 pass on flow and 2 pass on return) and two sizes of circulation pump (7 mt and 10 mt)
- Air and flue gas circuit with non-return valve
- Auto configuration of the MASTER - SLAVE system and the possibility to set up the switch on and off of the modules
- On-board electronics are able to manage a system with two direct zones and one DHW storage. For the mixed temperature zones the boiler can operate in conjunction with an external thermoregulation system
- RANGE RATED certified system to adapt the power generated to the system needs thus increasing the system efficiency and safeguarding the mechanics.
- Modules can be controlled remotely:
* Temperature and power with 0 - 10 Vdc signal
* Safety cut off switch and operated restart
* MODBUS and OPENTHERM communication protocol
-
Technical Data
FORCE W 60 W 80 W 99 W 120 W 150 ERP Class A - - - Fuel NG / LPG NG / LPG NG / LPG NG / LPG NG / LPG Heating max heat input kW 58 74.4 96.6 113 143 Heating min heat input kW 15 15 19 19 24 Heating max heat output (80/60°C) kW 57 72.9 94.7 110.5 140 Heating min heat output (80/60°C) kW 14.7 14.7 18.7 18.7 23.6 Heating max heat output (50/30°C) kW 60.8 77 100 117 148 Heating min heat output (50/30°C) kW 16.3 16.3 20.5 20.5 25.9 MaxP efficiency (80/60°C) % 98.3 98 98 97.8 97.8 MinP efficiency (80/60°C) % 98.3 98.3 98.3 98.3 98.3 MaxP efficiency (50/30°C) % 104.8 103.5 103.5 103.5 103.5 MinP efficiency (50/30°C) % 108.5 108.5 108 108 108 Efficiency 30% % 108.6 108.6 108.1 108.1 108.1 NOx emissions class - 6 6 6 6 6 NOx (O2=0%) weighted mg/kWh 50 54 39 38 40 MaxP flue gas temperature (80/60°C) °C 64 70 71 72 73 MinP flue gas temperature (80/60°C) °C 60 60 60 60 60 MaxP flue gas temperature (50/30°C) °C 44 48 53 54 54 MinP flue gas temperature (50/30°C) °C 30 30 30 30 30 MaxP flue gas flow rate g/s 26 34 44 51 65 MinP flue gas flow rate g/s 7 7 9 9 11 Max heating working pressure bar 6 6 6 6 6 Min heating working pressure bar 0.8 0.8 0.8 0.8 0.8 Max heating temperature °C 85 85 85 85 85 Protection rating IP IPX4D Supply voltage V/Hz 230/50 Absorbed electric power W 60 93 164 230 250 Heating water content litres 4.2 4.2 5.6 5.6 6.7 Empty weight kg 67 67 76 76 86 Appliance type B23 - C13 - C33 -
Manuals
-
Brochure