RGC

AIR-WATER CHILLERS AND HEAT PUMPS FOR INDOOR INSTALLATION

  • RGC

Unit type

IR Chiller

IP Heat pump (reversible on the refrigerant side)

BR Chiller Brine

BP Heat pump Brine (reversible on the refrigerant side)

 

Version

VB Base version

VD Desuperheater version

VR Total recovery version

 

Acoustic setting up

AB Base setting up

AS Low noise setting up

 

Source temperature level

M Medium temperature level

A High temperature level


  • Technical Data

    This series of air-water chillers and heat pumps satisfies the cooling and heating requirements of residential plants of medium size.

    All the units are suitable for indoor installation and can be applied to fan coil plants, radiant floor plants and high efficiency radiators plants.

    The refrigerant circuit, contained in a compartment protected from the air flow to simplify the maintenance operations, is equipped with scroll compressors mounted on damper supports, brazed plate heat exchanger, thermostatic expansion valve (standard for IR) or electronic expansion valve (standard for IP / option for IR), reverse cycle valve, dehydrator filter, double inlet centrifugal fans with forward curved blades, finned coil made of copper pipes and aluminium louvered fins with subcooling section.

    The circuit is protected by a safety gas valve, high and low pressure switches and differential pressure switch on the plate heat exchanger. The plate heat exchanger and all the hydraulic pipes are thermally insulated in order to avoid condensate generation and to reduce thermal losses.

    All the units can be equipped with variable speed fans control that allows the units to operate with low outdoor temperatures in cooling and high outdoor temperature in heating and permits to reduce noise emissions in such operating conditions.

    The low noise acoustic setting up (AS) is obtained, starting from the base setting up (AB), mounting sound jackets on the com- pressors and the technical compartment is clad with soundproofing material of suitable thickness.

    All the units are supplied with a management and control electrical panel containing general switch, phase presence and correct sequence controller, microprocessor controller with display and all the other electrical components with IP54 minimum protection degree.

    All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

     

    Options

    Storing and pumping module available in the configurations:

    • Storage tank arranged as buffer on the flow or as primary-secondary buffer

    • 1 or 2 pumps

    • Standard or high head pump

    • modulating pump Expansion valve

    • thermostatic

    • electronic (standard for IP) Compressor starting

    • standard (contactors)

    • soft starter Fans control

    • on-off control

    • modulating control (condensation / eva- poration control)

    Compressor power factor correction Electrical load protection

    • fuses

    • thermal magnetic circuit breakers Coil condensate tray

    (standard for IP)

     

    Accessories

    Rubber vibration dampers

    Spring vibration dampers

    Coil protection grilles

    Tank antifreeze electrical heater

    Remote control

    Modbus serial interface on RS485

    Programmer clock

    Phase sequence and voltage controller

    Low temperature kit (standard for IP)

    High and low pressure gauges

    High temperature thermostat Outdoor air sensor

    Water flow switch Victaulic hydraulic fittings


     

  • Technical Files

Related products

Pic
RCA - RNA
Water chillers and air/water heat pumps in class a with axial fans, scroll compressors and plate exchanger
Pic
RCO - RNO
Water chillers and air/water heat pumps with axial fans, scroll compressors and plate exchanger
Pic
RCI - RNI
Water chillers and air/water heat pumps in class a with axial fans, inverter scroll compressor and plate exchanger