OMNIA SW-T 3.2
REVERSIBLE AND SPLIT HEAT PUMPS WITH DC INVERTER COMPRESSOR AND INTEGRATED DHW STORAGE
Full Inverter split heat pumps with low environmental impact R32 gas with low environmental impact. The split installation has the advantage of avoiding any problem of freezing in the outdoor unit, even at the coldest temperatures (to -25°C) and in the absence of power.
OMNIA SW-T 3.2 is a heat pump, for heating and the production of domestic hot water, designed for applications in small and medium-sized housing units.
Each of its components has been designed with the renovation of existing heating systems in mind and for the replacement of boilers and electric water heaters, ensuring the same comfort, with an efficient and environmentally friendly solution.
All the units meet the most extreme winter climate control requirements, in fact they can produce hot water up to 65°C, which makes them suitable for practically all heating systems.
The generators consist of an outdoor unit with the heart of the cooling circuit, from the compressor to the fan with the air side exchanger, which will be connected to the refrigerant gas pipes towards the indoor unit which, instead, contains the hub of the hydraulic circuit (complete with all system components) and the 100-liter DHW storage tank.
The indoor unit is also equipped with two electrical integrations: 3kW for the heating system and 1.2 kW for DHW production.
The new Full Inverter concept by Ferroli uses DC inverter modulations on the 3 main energy-intensive components of the machine, i.e. compressor, fan and pump. This makes it possible to modulate the power by finely tracking the thermal load and offering the user very high efficiencies and significant energy saving.
The Ferroli Full Inverter concept also makes it possible to reduce inrush currents, avoiding sudden changes in the grid and ensuring a longer service life for the components.
The quality of the components and production processes has made it possible to achieve one of the lowest noise levels among the units on the market today.
-
Technical Data
THE CONTROL SYSTEM
The user interface is equipped with Capsense technology with a 2.8" graphic display, which allows the user to interact easily and simply. The interface on the machine communicates with the Connect CRP systems, which can manage up to 8 thermostats (7 Connect CRP Zone + 1 Connect CRP) divided into 2 zones, one direct and one mixed.
MODBUS PROTOCOL for smart management via possible external BMS
HEATING AND COOLING with singular generator and heat pump. Full Inverter modulation makes it possible to maintain the desired setpoints, optimizing consumption for the user. The setting of climate curves (as standard) can improve comfort and further reduce consumption
DOMESTIC HOT WATER (DHW) PRODUCTION It activates when the DHW temperature probe goes below the DHW setpoint
ADDITIONAL ENERGY SOURCES (heating elements). The heat pump can activate these additional sources in Integration or Replacement, based on customizable parameters. In addition to these settings, the call can occur in an emergency, where the heat pump is faulty
PHOTOVOLTAIC AND GRID SMART GRID INPUTS The unit is equipped with 2 digital inputs (Smart Grid contacts) for managing an input from the photovoltaic system and from the electricity grid and optimizing consumption and bill costs
REMOTE CONTROL VIA APP Available for iOS and Android in combination with Connect CRP (optional)
DHW STORAGE TANK HEATING ELEMENT In DHW mode, the unit manages a heating element inserted in the storage tank as integration, anti-legionella function or as a reserve source, in case of a fault
FAST DHW A function to give priority to DHW production by activating all available energy sources, to bring the DHW storage tank to the setpoint in the shortest possible time
ANTI-LEGIONELLA FUNCTION For setting anti-legionella weekly cycles.
SILENT MODE Reduces compressor frequency and fan speed to reduce noise. 2 different levels are available, programmable in daily time bands (e.g. night)
ON/OFF from external contact. The unit can be activated and deactivated via an external contact (e.g. from a zone thermostat): in this case the operating mode will follow the controller settings
HEAT/COOL from external contacts. The unit can receive a summer/winter switching signal from outside (e.g. from the zone thermostat)
ECO Dedicated setpoint for “Eco” operation. Settable also for time bands
WEEKLY TIME PROGRAMMING The Connect CRP (optional) allows time programming for each day of the week by defining the mode (COOL/HEAT/DHW) and setpoint for each band
FROST PROTECTION with heat pump working in heating mode with circulating pump ON and possible electric booster
-