HXP

RENEWABLES / AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION

  • HXP
  • HXP

THE RANGE

Unit type

IP Reversible heat pump

(reversible on the refrigerant side)

 

Versions (heat recovery)

VB Base version

VD Desuperheater version

 

Acoustic setting up

AB Base setting up


  • Technical Data

    This series of air-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of residential plants of small and medium size.

    All the units are suitable both for outdoor or indoor installation and can be applied to fan coil plants, radiant floor plants and high efficiency radiators plants.

    The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available.

    The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdo-or temperature through climatic curves adaptable to the building features. It's possible to manage a storage tank and two independent circuits (a direct one and a mixed one).

    The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary).

    The cooling function can be realized through "active cooling" (refrigerant circuit inversion). When the unit is used in radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed. During cooling mode operation a part of the heating power in excess can be recovered for the domestic hot water production (VD version).

    The internal programmer clock allows to define different daily switching programs for heating, cooling and domestic hot water production.

    The refrigerant circuit, contained in a box repaired from the air flow to simplify the maintenance operations, is equipped with scroll compressor mounted on damper supports, brazed plate heat exchangers, electronic expansion valve, reverse cycle valve, centrifugal fan (plug fan), finned coil realized with copper pipes and aluminium fins. The circuit is protected by high and low pressure switches and flow switches on the plate heat exchanger.

    The plate heat exchanger and all the hydraulic pipes are thermally insulated in order to avoid condensate generation and reduce thermal losses.

Related products

Pic
OMNIA M 3.2
Reversible heat pump for outdoor installation with dc inverter compressor
Pic
OMNIA S 3.2
Split system reversible heat pump with dc inverter compressor
Pic
OMNIA ST 3.2
Air-water reversible heat pumps for split installation, with built-in dhw storage tank
Pic
OMNIA M 3.2 22T÷30T
Reversible heat pump for outdoor installation with dc inverter compressor